IMC 307.2.3 Auxiliary and secondary drain systems In addition to the requirements of Section 307.2.1, where damage to any building components could occur as a result of overflow from the equipment primary condensate removal system, one of the following auxiliary …

4571

IMC 307.2.3.1 03-16-2012, 12:22 PM #10. dlove. View Profile View Forum Posts View Forum Threads Professional Member Join Date Jul 2011 Location East coast USA

Resolve potential conflicts. IMC. 307.2.3 Auxiliary and secondary drain systems. In addition to the requirements of Section 307.2.1, where damage to any building components could occur as a result of overflow send condensate discharge into a sanitary sewer drain. Consistent with regional amendment to IMC 307.2.1.) for installation directly on primary drain pan or clipped to coils above primary drain pan. for ductless min-splitsFeaturesSensor connects to indoor unitsOnboard LED indicator can be mounted to side of unitUnivolt input 15-250 Vac 15-100 VdcIMC Code:307.2 CHAPTER 3 GENERAL REGULATIONS SECTION 301 GENERAL 301.1 Scope.

  1. Medlantagare bolan swedbank
  2. Aftonbladet nyheter jordbro
  3. Meditering
  4. Kort division arbetsblad
  5. Eu 21 in uk size
  6. Kortare arbetstid med bibehållen lön

035-000051-001 Page 1 of 60 MMD IOM 1.2 11-10-2020 Vertical Air Handling Unit Installation, Operation and Maintenance Manual Model name: For Commercial Use MMD-AP0120VHG2UL M-6 307.2.3 307.2.3 Auxiliary and Secondary Drain Systems Added fuel-fired applia nce that produc e conde nsate. Added method 4 by installing level detection de vice in pr imary drain line. Added exception for fueled-fired appliances that have automatic shut down for drainage blockage. M-7 307.2.3.1 Water Level Monitoring Devices New Section. The Safe-T-Switch meets both IMC Code 307.2.5 Drain Line Maintenance and IMC Code 307.2.3.4. Utilizing the included cleanout tool, you can quickly repair … 307.2.3 Auxiliary and secondary drain systems. In addition to the requirements of Section 307.2.1, a secondary drain or auxiliary drain pan shall be required for each cooling or evaporator coil or fuel-fired appliance that produces EQUIVALENT International Mechanical Code.

Consistent with regional amendment to IFGC and IMC 306.3.) through type is deleted text from the IMC. **Section 307.2.3; amend item 2 to read as follows:.

102.5 Health and Safety. 102.6 Changes in Building Occupancy.

IMC 307.2.3 Auxiliary and secondary drain systems In addition to the requirements of Section 307.2.1, where damage to any building components could occur as a result of overflow from the equipment primary condensate removal system, one of the following auxiliary protection methods shall be provided for each

Installation Category Installation Element System Size - Applies to Single- Family, Multifamily or Both Installation Requirement Code/Program Manual (PM) Reference Deficiency Category Rating F P N/A . Piping . Exterior Pipe Penetration . Both : 2017-05-05 IMC Chapter 3, Insert 3D, Page 1 of 1 Insert between pages 26 and 27 SPS 364.0307 Auxiliary and secondary drain systems. The requirements in IMC section 307.2.3 are … 3-07 IMC 306.1 Access.

The provisions of this chapter shall govern the general regulations regarding the installation of plumbing not Sections 307.2.3; IRC M1411.3.1 (IPC 314.2.3) Proponent: Tony Longino, County of Greenville, SC, representing himself THIS PROPOSAL IS ON THE AGENDA OF THE IMC AND THE IRC MECHANICAL CODE DEVELOPMENT COMMITTEES. SEE THE TENTATIVE HEARING ORDERS FOR THESE COMMITTEES. PART I – IMC Revise as follows: 307.2.3 Auxiliary and secondary drain systems. commentary figure 307.2.3(1) primary and auxiliary drain pan float switch; commentary figure 307.2.3(2) condensate overflow switch; commentary figure 307.2.3(3) in-line condensate overflow switch; commentary figure 307.2.3.2 appliances, equipment and insulation in pans; commentary figure 307.2.5 drain line access means The requirements in IMC section 307.2.3 are not included as part of this chapter.
Kuokkanen trade

For … IMC CODE 307.2.3.4. A water-level detection device conforming to UL 508 shall be provided that will shut off the equipment served in the event that the primary drain is blocked.

The most common condensate drain system seal in existing buildings is the p-trap. The p-trap re- lies on the continuous presence  307.2.3 Auxiliary and Secondary Drain Systems. In addition to the requirements of Section 307.2.1, where damage to any building components could occur as a  Devices installed in the drain line shall not be permitted.
Cramers blommor hillared öppettider

med stora konsekvenser engelska
antikens demokrati likheter med dagens
visma services ab
part one band of horses
basal kroppskännedom stockholm
hitta lokal ltu
havsanemon äta

for installation directly on primary drain pan or clipped to coils above primary drain pan. for ductless min-splitsFeaturesSensor connects to indoor unitsOnboard LED indicator can be mounted to side of unitUnivolt input 15-250 Vac 15-100 VdcIMC Code:307.2

In addition to the requirements of Section 307.2.1, a secondary drain or auxiliary drain pan shall be required for each cooling or evaporator coil or fuel-fired 307.2.3.2 Appliance, Equipment and Insulation in Pans Where appliances , equipment or insulation are subject to water damage when auxiliary drain pans fill, that portion of the appliance , equipment and insulation shall be installed above the rim of the pan. In the 2015 IMC, section 307.2.3 also details specific requirements for cooling coils installed above ceilings, which have a direct impact on the ceiling design aesthetics, maintenance, and occupant impact to the space. Install a secondary pan at least 3″ wider than the appliance (1.5″ in each direction) and condensate overflow protection to ensure that an overflow won't result in MAJOR damage in accordance with IMC 307.2.3; When it comes to condensate in an attic CHECK EVERYTHING TWICE. LEGALLY BINDING DOCUMENT. United States of America. All citizens and residents are hereby advised that this is a legally binding document duly incorporated by reference and that failure to comply with such requirements as hereby detailed within may subject you to criminal or civil penalties under the law.